The Simple Logger® II Model L102 is a two channel recording device powered by two alkaline batteries. Line tracking is performed such that 64 samples over one line cycle are taken.
Description
Receive 1-3 days from order
The Simple Logger® II Model L102 is a two channel recording device powered by two alkaline batteries. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency 50 or 60Hz. Harmonic measurements are calculated from these 64 samples.
Harmonics are only available from the Simple Logger® II Control Panel within the free DataView® software included with the unit. The L102 records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the inputs are ignored between measurement intervals.
Product Features:
Compatible standard current probes with voltage output and BNC connection (sold separately)
2 inputs (Model L102)
64 samples per cycle
Programmable storage rates from 8 every second to 1 every day
4 user selectable storage modes
Stores up to 240,000 measurements in non-volatile memory
Powered by standard Alkaline batteries
Lightweight, compact, fits anywhere
5 LED indicators quickly and clearly display logger status
Includes FREE DataView® software for data storage, real-time display, analysis and report generation
Optically isolated USB 2.0 communication cable included
EN 61010-1; 50V CAT III
Applications:
Split phase load monitoring
Neutral & ground current monitoring
Intermittent problem detection
Harmonic current monitoring using DataView® software
To contact ESIS about Chauvin Arnoux Current Data Logger | L102 use Get a quote.
The Simple Logger® II Model L102 is a two channel recording device powered by two alkaline batteries. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency 50 or 60Hz. Harmonic measurements are calculated from these 64 samples.
Harmonics are only available from the Simple Logger® II Control Panel within the free DataView® software included with the unit. The L102 records TRMS at a rate of up to eight times per second. The measurement process is performed no more than eight times per second. TRMS calculations are performed on a single line cycle. This means that the inputs are ignored between measurement intervals.
Product Features:
Compatible standard current probes with voltage output and BNC connection (sold separately)
2 inputs (Model L102)
64 samples per cycle
Programmable storage rates from 8 every second to 1 every day
4 user selectable storage modes
Stores up to 240,000 measurements in non-volatile memory
Powered by standard Alkaline batteries
Lightweight, compact, fits anywhere
5 LED indicators quickly and clearly display logger status
Includes FREE DataView® software for data storage, real-time display, analysis and report generation
Optically isolated USB 2.0 communication cable included
EN 61010-1; 50V CAT III
Applications:
Split phase load monitoring
Neutral & ground current monitoring
Intermittent problem detection
Harmonic current monitoring using DataView® software
Trade With Confidence. The supplier of this item is approved as a Verified Supplier. Business registration, contact details and locations have been verified. ESIS are also proudly displaying these credentials: