SPECIFICATIONS |
GENERAL
|
Contrast Enhancement |
FSX® / Histogram equalization (IR only) |
OVERVIEW
|
Accuracy |
±2°C or ±2% of reading, for ambient temperature 15°C–35°C and object temperature above 0°C |
Alarm Functions |
On any selected measurement function, digital in, and internal camera temperature |
Alarm Output |
• Digital out • E-mail (SMTP) (push) • EtherNet/IP (pull) • File transfer (FTP) (push) • Modbus TCP slave (pull) • MQTT (push) • Query over RESTful API (pull) • Store image or video |
Base Mounting |
4× M4 on 4 sides |
Encoding |
H.264, MPEG4, or MJPEG |
Housing material |
Aluminium |
IR Resolution |
320 × 240 |
Object Temperature Range |
-20°C to 120°C, 0°C to 650°C , 300°C to 2000°C |
Size (L x W x H) |
123 × 77 × 77 mm |
Thermal Sensitivity/NETD |
Lens dependent |
Web interface |
Yes |
Weight |
0.82 kg (1.8 lb), camera only |
Multi-Streaming |
Yes |
CONNECTIONS & COMMUNICATIONS
|
|
Digital I/O connector type |
M12 12-pin A-coded, Male (shared with external power) |
Digital I/O isolation voltage |
500 VRMS |
Digital input purpose |
NUC, NUC disable, alarm |
Digital Inputs |
2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V |
Digital Output Purpose |
• As a function of alarm, output to external device • Fault (NC) |
Digital Outputs |
3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC) |
Ethernet |
For control, result, image, and power |
Ethernet Communication |
TCP/IP socket-based FLIR proprietary |
Ethernet Protocols |
• EtherNet/IP • IEEE 1588 • Modbus TCP Slave • MQTT • SNMP • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP |
RS-232 |
NA |
Multicast |
Yes |
EMC |
• ETSI EN 301 489-1 (radio) • ETSI EN 301 489-17 (radio) • EN 61000-4-8 (magnetic field) • FCC 47 CFR Part 15 Class B (emission US) • ISO 13766-1 (EMC - Earth-moving and building construction machinery) • EN ISO 14982 (EMC - Agricultural and forestry machinery) |
Operating Temperature Range |
-20°C to 50°C : • -20°C to 40°C (in free air) • 40°C to 50°C (mounted on cooling plate accessory) Maximum camera case temperature: 65°C |
Tripod Mounting |
UNC ¼″-20 on 2 sides |
FILE STORAGE & DATA TRANSFER
|
Available Lenses |
6°, 24°, 14°, 42° |
Focus |
One-shot contrast, motorized, and manual |
Radiometric IR video streaming |
NA |
Video Streaming |
RTSP protocol |
Overlay |
With / Without |
Visible Camera |
Optional accessory |
MEASUREMENT & ANALYSIS
|
External Optics & Windows Correction |
Based on input of optics/window transmission and temperature |
Measurement Corrections |
Global object parameters; local parameters per analyze function |
Measurement Presets |
Yes |
Reflected apparent temperature correction |
Based on input of reflected temperature |
Measurement Tools |
10 spotmeters, 10 boxes, 3 Deltas (difference any value/reference/external lock), 1 isotherm (above/below/interval), 1 iso-coverage, 1 reference temperature |
Automatic hot & cold detection |
Max./min. temperature value and position shown within box |
POWER
|
External Power Operation |
24/48 V DC 8 W max |
Power Connection |
M12 12-pin A-coded, male (shared with Digital I/O) |
Power Consumption |
• 7.5 W at 24 V DC typical • 7.8 W at 48 V DC typical • 8.1 W at 48 V PoE typical |
External Voltage |
Allowed range 18–56 V DC |
RADIOMETRY
|
Image Source |
Video stream 0: visual / IR / MSX® (visual camera is an optional feature) Video stream 1: visual |
STORAGE MEDIA
|
Image Storage |
Records up to 100 FLIR radiometric JPEG; storage as function of: alarm, scheduling, or user interaction (camera web |