The QED attenuators increase the energy, energy density, average power and average power density capabilities of the QE Series detectors.
Description
17 Recent ViewsIn Stock
They are engineered to typically transmit 30-50% (@1.064 µm) of the incident radiation to the detector in a near Lambertian pattern (very wide diffusion pattern). Their slide-in casing make them easy to install and remove and they are held securely in place with the use of simple set screws. Since they become part of the detector, it is important to understand how they will affect the calibration.
STANDARD CALIBRATION
QE Detector Alone: Fully calibrated, from 248 - 2500 nm
With QED Attenuator: Not calibrated (Calibrated by the user)
EXTRA QED CALIBRATION QED-CAL-1
QE Detector Alone: Fully calibrated, from 248 - 2500 nm
With QED Attenuator: Calibrated at one wavelength (532 nm or 1064 nm)
CALIBRATED AS A PAIR (-QED) QED-CAL-2
QE Detector Alone: Not calibrated
With QED Attenuator: Fully calibrated, from 308 - 2100 nm
FULL CALIBRATION QED-CAL-3
QE Detector Alone: Fully calibrated, from 248 - 2500 nm
With QED Attenuator: Fully calibrated, from 308 - 2100 nm (This configuration comes with a DB-15 adaptor for the QED calibration)
To contact Lastek about Laser Energy Detectors -QE25HR-H-MB-D0 use Get a quote.
They are engineered to typically transmit 30-50% (@1.064 µm) of the incident radiation to the detector in a near Lambertian pattern (very wide diffusion pattern). Their slide-in casing make them easy to install and remove and they are held securely in place with the use of simple set screws. Since they become part of the detector, it is important to understand how they will affect the calibration.
STANDARD CALIBRATION
QE Detector Alone: Fully calibrated, from 248 - 2500 nm
With QED Attenuator: Not calibrated (Calibrated by the user)
EXTRA QED CALIBRATION QED-CAL-1
QE Detector Alone: Fully calibrated, from 248 - 2500 nm
With QED Attenuator: Calibrated at one wavelength (532 nm or 1064 nm)
CALIBRATED AS A PAIR (-QED) QED-CAL-2
QE Detector Alone: Not calibrated
With QED Attenuator: Fully calibrated, from 308 - 2100 nm
FULL CALIBRATION QED-CAL-3
QE Detector Alone: Fully calibrated, from 248 - 2500 nm
With QED Attenuator: Fully calibrated, from 308 - 2100 nm (This configuration comes with a DB-15 adaptor for the QED calibration)