The RTDTempX Series includes 4, 8, 12, and 16-channel RTD-based temperature data loggers.
Description
Documents
Multi-Channel Temperature Data Logger
86 Recent Views
Applications for this product
Temperature data logging/Monitoring through an external RTD Probe
Up to 16 temperature channels can be monitored from one device
Features of this product
Accepts 2, 3 and 4-Wire RTDs
Memory Capacity of 2,700,000+ Readings
Measures Temperatures from -200 °C to +850 °C
Specifications of this product
Reading Rate
4 Hz up to 1 reading every 24 hours
Channels
4, 8, 12, 16
Battery Life
18 Months
Material
Black anodized aluminum
Dimensions
4-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm) 8-channel: 2.70 in x 7.25 in x 1.22 in(65.6 mm x 184.2 mm x 31.0 mm) 12-channel: 2.70 in x 7.25 in x 1.68 in(65.6 mm x 184.2 mm x 42.7 mm) 16-channel: 2.70 in x 7.25 in x 2.14 in(65.6 mm x 184.2 mm x 54.4 mm)
Operating Environment
-20 ºC to +60 ºC (-4 ºF to +140 ºF),0 %RH to 95 %RH non-condensing
Temperature
Temperature Sensor
External: 2,3, or 4 wire RTD
Temperature Range
18.5 Ω to 390.5 Ω -200 ºC to +850 ºC (-328 ºF to +1562 ºF) (Probe Dependent)
The RTDTempX Series includes 4, 8, 12 and 16-channel RTD-based temperature data loggers. This series accepts 2, 3 and 4-wire RTDs to measure and record temperatures from -200 ºC to +850 ºC (-328 ºF to +1562 ºF) with a calibration accuracy of ±0.04 °C (±0.072 °F), all probe dependent.
The RTDTempX Series packs a memory capacity of 2,794,236 readings. To maximize memory capacity, users can enable or disable channels. There’s no interface necessary, the RTDTempX Series uses standard USB-A to Micro USB cable.
The RTDTempX Series is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
To contact Pacific Sensor Technologies Pty Ltd about MadgeTech RTDTempX - RTD-based temperature data logger use Get a quote.
Applications for this product
Temperature data logging/Monitoring through an external RTD Probe
Up to 16 temperature channels can be monitored from one device
Features of this product
Accepts 2, 3 and 4-Wire RTDs
Memory Capacity of 2,700,000+ Readings
Measures Temperatures from -200 °C to +850 °C
Specifications of this product
Reading Rate
4 Hz up to 1 reading every 24 hours
Channels
4, 8, 12, 16
Battery Life
18 Months
Material
Black anodized aluminum
Dimensions
4-channel: 2.70 in x 7.25 in x 1.22 in (65.6 mm x 184.2 mm x 31.0 mm) 8-channel: 2.70 in x 7.25 in x 1.22 in(65.6 mm x 184.2 mm x 31.0 mm) 12-channel: 2.70 in x 7.25 in x 1.68 in(65.6 mm x 184.2 mm x 42.7 mm) 16-channel: 2.70 in x 7.25 in x 2.14 in(65.6 mm x 184.2 mm x 54.4 mm)
Operating Environment
-20 ºC to +60 ºC (-4 ºF to +140 ºF),0 %RH to 95 %RH non-condensing
Temperature
Temperature Sensor
External: 2,3, or 4 wire RTD
Temperature Range
18.5 Ω to 390.5 Ω -200 ºC to +850 ºC (-328 ºF to +1562 ºF) (Probe Dependent)
The RTDTempX Series includes 4, 8, 12 and 16-channel RTD-based temperature data loggers. This series accepts 2, 3 and 4-wire RTDs to measure and record temperatures from -200 ºC to +850 ºC (-328 ºF to +1562 ºF) with a calibration accuracy of ±0.04 °C (±0.072 °F), all probe dependent.
The RTDTempX Series packs a memory capacity of 2,794,236 readings. To maximize memory capacity, users can enable or disable channels. There’s no interface necessary, the RTDTempX Series uses standard USB-A to Micro USB cable.
The RTDTempX Series is compatible with the latest MadgeTech 4 Software making starting, stopping, and downloading simple and easy. Graphical, tabular, and summary data is provided for analysis and can be viewed as customizable engineering units.
Customers: Pfizer, CSIRO, ANSTO, Rio Tinto, In-Vitro, Device Technologies, Australian Universities
Trade With Confidence. The supplier of this item is approved as a Verified Supplier. Business registration, contact details and locations have been verified. Pacific Sensor Technologies Pty Ltd are also proudly displaying these credentials:
Established:
2005
Employees:
6-20
Customers:
Pfizer, CSIRO, ANSTO, Rio Tinto, In-Vitro, Device Technologies, Australian Universities