Enersine Pro 60A – 2400A Modular APF – Active Power Filter
Description
In Stock
Modular and Scalable System Architecture
Universal Voltage: 208V/400V/480V without transformer
Harmonic compensation for 3-wire or/and 4-wire system
Eliminates harmonics current from 2nd to 51st order
Programmable Harmonics Compensation and Power Factor Correction
EnersineTM APF measures and monitors the entire load current through external auxiliary coupling current transformers (CT) mounted on the AC line, removes the fundamental frequency component and injects opposite phase harmonic current to cancel harmonic current in the electrical distribution system.
By cancelling the harmonic currents in the circuit, there will be:
Powerful Performance
Eliminates harmonics current from 2nd to 51st order
Close/Open Loop Selectable Control
Ultra-fast response to load changes within microseconds
Load balancing between phases and unload neutral wire
Programmable Harmonics Compensation and Power Factor Correction
Programmable Filtering Mode Options
Harmonic compensation only
Power Factor (Reactive Current) compensation only
Harmonic compensation priority + Power Factor Compensation
Power Factor Compensation Priority + Harmonic compensation
Harmonic compensation priority + Power Factor Compensation + Load Balancing
Expandable Capabilities
Space-saving high power density design
Different rated current filter system can be wired in Parallel with common coupling CT
Typical Application
Data centres, semiconductor and electronics manufacturers.
To contact Helios Power Solutions about Modular Active Harmonic Filter | Enersine Pro 60A use Get a quote.
Modular and Scalable System Architecture
Universal Voltage: 208V/400V/480V without transformer
Harmonic compensation for 3-wire or/and 4-wire system
Eliminates harmonics current from 2nd to 51st order
Programmable Harmonics Compensation and Power Factor Correction
EnersineTM APF measures and monitors the entire load current through external auxiliary coupling current transformers (CT) mounted on the AC line, removes the fundamental frequency component and injects opposite phase harmonic current to cancel harmonic current in the electrical distribution system.
By cancelling the harmonic currents in the circuit, there will be:
Powerful Performance
Eliminates harmonics current from 2nd to 51st order
Close/Open Loop Selectable Control
Ultra-fast response to load changes within microseconds
Load balancing between phases and unload neutral wire
Programmable Harmonics Compensation and Power Factor Correction
Programmable Filtering Mode Options
Harmonic compensation only
Power Factor (Reactive Current) compensation only
Harmonic compensation priority + Power Factor Compensation
Power Factor Compensation Priority + Harmonic compensation
Harmonic compensation priority + Power Factor Compensation + Load Balancing
Expandable Capabilities
Space-saving high power density design
Different rated current filter system can be wired in Parallel with common coupling CT
Typical Application
Data centres, semiconductor and electronics manufacturers.
Trade With Confidence. The supplier of this item is approved as a Verified Supplier. Business registration, contact details and locations have been verified. Helios Power Solutions are also proudly displaying these credentials: