Thermal Mass Flow Meter | FCI ST100 Series ...
Production and refinery engineers responsible for measuring, monitoring and flaring waste gas will find the advanced ST100 Series Thermal Mass Flow Meter from Fluid Components International (FCI) with FCI's VeriCal™ In-Situ Calibration Verification System combines precise air/gas measurement capability with the convenience of in-situ calibration verification.
The ST100 Flow Meter with the VeriCal In-Situ Calibration System is designed to comply with the US Minerals Management Service (MMS) mandate per final rule, 30 CFR Part 250, Subpart K, Section 250, stipulating that all domestic US offshore rigs processing more than an average of 2000 bopd must install flare/vent gas flow meters. These regulations are intended to protect the environment through the monitoring of greenhouse gases (GHG).
Validating flow meter calibration to meet regulatory requirements is no longer labor-intensive, costly or challenging with the VeriCal In-Situ Calibration System. The system verifies flow meter calibration in minutes without removing the meter from the pipe or process. In the past, flow meters had to endure the cost and hassle of being pulled from the process, then returned to the manufacturer or a calibration lab for testing and then shipped back for re-installation.
The ST100 Series Flow Meter sets a new industry benchmark in process and plant air/gas flow measurement, offering the most feature-rich and function-rich electronics available. The ST100’s performance delivers unsurpassed adaptability and value to meet plant gas flow measurement applications for today and tomorrow.
Whether the need is for 4-20 mA analogue, frequency/pulse, alarm relays or digital bus communications such as HART, Fieldbus, Profibus or Modbus, the ST100 is the solution. Should a plant’s needs change over time or an upgrade be desirable, the ST100 Flow Meter adapts as necessary with a plug-in card replacement that can be changed out by plant technicians in the field.
The ST100 Flow Meter's unique graphical, multivariable, backlit LCD display/readout brings new meaning to the term "process information". It provides the industry's most comprehensive information with continuous display of all process measurements and alarm status, and the ability to interrogate for service diagnostics.
The user-friendly ST100 stores up to five unique calibration groups to accommodate broad flow ranges, differing mixtures of the same gas and multiple gases, and obtains up to 1000:1 turndown. Also standard is an on-board data logger with an easily accessible, removable 2-GB micro-SD memory card capable of storing 21 million readings.
Features:
To contact AMS Instrumentation & Calibration about Thermal Mass Flow Meter | FCI ST100 Series use Get a quote.
Production and refinery engineers responsible for measuring, monitoring and flaring waste gas will find the advanced ST100 Series Thermal Mass Flow Meter from Fluid Components International (FCI) with FCI's VeriCal™ In-Situ Calibration Verification System combines precise air/gas measurement capability with the convenience of in-situ calibration verification.
The ST100 Flow Meter with the VeriCal In-Situ Calibration System is designed to comply with the US Minerals Management Service (MMS) mandate per final rule, 30 CFR Part 250, Subpart K, Section 250, stipulating that all domestic US offshore rigs processing more than an average of 2000 bopd must install flare/vent gas flow meters. These regulations are intended to protect the environment through the monitoring of greenhouse gases (GHG).
Validating flow meter calibration to meet regulatory requirements is no longer labor-intensive, costly or challenging with the VeriCal In-Situ Calibration System. The system verifies flow meter calibration in minutes without removing the meter from the pipe or process. In the past, flow meters had to endure the cost and hassle of being pulled from the process, then returned to the manufacturer or a calibration lab for testing and then shipped back for re-installation.
The ST100 Series Flow Meter sets a new industry benchmark in process and plant air/gas flow measurement, offering the most feature-rich and function-rich electronics available. The ST100’s performance delivers unsurpassed adaptability and value to meet plant gas flow measurement applications for today and tomorrow.
Whether the need is for 4-20 mA analogue, frequency/pulse, alarm relays or digital bus communications such as HART, Fieldbus, Profibus or Modbus, the ST100 is the solution. Should a plant’s needs change over time or an upgrade be desirable, the ST100 Flow Meter adapts as necessary with a plug-in card replacement that can be changed out by plant technicians in the field.
The ST100 Flow Meter's unique graphical, multivariable, backlit LCD display/readout brings new meaning to the term "process information". It provides the industry's most comprehensive information with continuous display of all process measurements and alarm status, and the ability to interrogate for service diagnostics.
The user-friendly ST100 stores up to five unique calibration groups to accommodate broad flow ranges, differing mixtures of the same gas and multiple gases, and obtains up to 1000:1 turndown. Also standard is an on-board data logger with an easily accessible, removable 2-GB micro-SD memory card capable of storing 21 million readings.
Features:
To contact AMS Instrumentation & Calibration about Thermal Mass Flow Meter | FCI ST100 Series use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product