The FA (Front Access) series is designed to be used in telecommunication applications with 12 years design life in float service. The Front Access connection and 12 years design life, easy installation and maintenance are possible due to the combination of the newly developed paste formula with up-to-date AGM structures used in the design of this range.
The FA Series is also widely used in UPS systems and other back up applications.
Features and Benefits
12 years design life in floating condition
Wide operating temperature range from -15°C to 60°C
Advanced paste formula with increased recharge efficiency
Front access terminal with standard width for 19″ and 23″ ETSI racks
30% decreased float current lead to excellent high temperature resistance
Thick flat plate with high Tin low Calcium alloy
Low self-discharge rate
Excellent deep discharge recovery capability
Construction
Positive plate : Thick high Sn low Ca grid minimize corrosion and prolong life Negative plate : Balanced Pb-Ca grid for improved recombination efficiency
Separator: Advanced AGM separator for ultra low float current
Electrolyte : Dilute high purity sulphuric acid
Battery container and cover: ABS
Pillar seal : 100% factory tested, proven two layers epoxy resin seal
Relief valve: Complete with integrated flame arrestor
Charging Voltage and Settings
Constant voltage charging is recommended
Recommended float charge voltage: 2.25Vpc @ 25 °C
Float voltage temperature compensation: -3mV /° C/cell
To contact Aeson Power about Aeson Power Lead Acid Industrial Batteries | FA Series use Get a quote.
The FA (Front Access) series is designed to be used in telecommunication applications with 12 years design life in float service. The Front Access connection and 12 years design life, easy installation and maintenance are possible due to the combination of the newly developed paste formula with up-to-date AGM structures used in the design of this range.
The FA Series is also widely used in UPS systems and other back up applications.
Features and Benefits
12 years design life in floating condition
Wide operating temperature range from -15°C to 60°C
Advanced paste formula with increased recharge efficiency
Front access terminal with standard width for 19″ and 23″ ETSI racks
30% decreased float current lead to excellent high temperature resistance
Thick flat plate with high Tin low Calcium alloy
Low self-discharge rate
Excellent deep discharge recovery capability
Construction
Positive plate : Thick high Sn low Ca grid minimize corrosion and prolong life Negative plate : Balanced Pb-Ca grid for improved recombination efficiency
Separator: Advanced AGM separator for ultra low float current
Electrolyte : Dilute high purity sulphuric acid
Battery container and cover: ABS
Pillar seal : 100% factory tested, proven two layers epoxy resin seal
Relief valve: Complete with integrated flame arrestor
Charging Voltage and Settings
Constant voltage charging is recommended
Recommended float charge voltage: 2.25Vpc @ 25 °C
Float voltage temperature compensation: -3mV /° C/cell