TMC produces dry type rectifier transformers with capacities up to 10MVA Duty Cycle 6 and voltages up to 36kV.
Rectifier Transformer Characteristics
Transformers for 12 pulse and 24 pulse rectifiers. Star/Delta, interconnected star (zigzag) and polygon connections. Close coupling between secondaries is normal, loose coupling is also available.
Secondary terminations can be arranged to align with rectifier connections. Duty cycle derating is available.
Enclosures
The transformers can be supplied in enclosures to various degrees of protection, or open (un-enclosed) if preferred. Enclosure ratings of IP21 to IP33 are common and protection up to IP66 is also available for extreme conditions and flameproof applications.
Enclosures are fitted with sealed marshalling boxes for temperature and performance monitoring equipment. Enclosures can be fitted with interlocked doors and limit switches to provide additional safety.
Fan Cooling
TMC dry type transformers can be supplied with fans to increase the rated capacity (kVA). Forced directed air circulation permits a continuous power increase of up to 35% above the rated capacity.
Fans can be used to economically provide extra capacity for overload conditions such as cyclic load peaks and traction loads.
Information Required with Enquiry:
BROCHURE
Download PDF brochure HERE (2.11Mb)
To Know More about Dry Type Transformers For Rectifiers Please click here
To contact TMC Australia about Dry Type Transformers For Rectifiers use Get a quote.
Dry Type Transformers for Rectifiers
Dry Type Transformers
TMC produces dry type rectifier transformers with capacities up to 10MVA Duty Cycle 6 and voltages up to 36kV.
Rectifier Transformer Characteristics
Transformers for 12 pulse and 24 pulse rectifiers. Star/Delta, interconnected star (zigzag) and polygon connections. Close coupling between secondaries is normal, loose coupling is also available.
Secondary terminations can be arranged to align with rectifier connections. Duty cycle derating is available.
Enclosures
The transformers can be supplied in enclosures to various degrees of protection, or open (un-enclosed) if preferred. Enclosure ratings of IP21 to IP33 are common and protection up to IP66 is also available for extreme conditions and flameproof applications.
Enclosures are fitted with sealed marshalling boxes for temperature and performance monitoring equipment. Enclosures can be fitted with interlocked doors and limit switches to provide additional safety.
Fan Cooling
TMC dry type transformers can be supplied with fans to increase the rated capacity (kVA). Forced directed air circulation permits a continuous power increase of up to 35% above the rated capacity.
Fans can be used to economically provide extra capacity for overload conditions such as cyclic load peaks and traction loads.
Information Required with Enquiry:
BROCHURE
Download PDF brochure HERE (2.11Mb)
To Know More about Dry Type Transformers For Rectifiers Please click here
To contact TMC Australia about Dry Type Transformers For Rectifiers use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product