RadioLinx Lightning Protection | LP-24002 ...
Features and Benefits
LP-24002
The LP-24002 lightning protection is designed for use inside an enclosure with the bulkhead fitting protruding through the enclosure. The connectors are standard N jack connector to standard N jack BH connector. The bulkhead fitting can be connected to any standard N type connector extension cable.
LP-24003
The LP-24003 lightning protection is designed for use inside an enclosure with the bulkhead fitting protruding through the enclosure and connecting to a N plug barrel adapter. This can then connect to any antenna with a standard N type connector.
Applications
RadioLinx Lightning Protection is designed to protect the radio in the event of a lightning strike. A minimum 6 gauge copper wire should be used to connect the lightning protection to earth ground.
Hardware Specifications
Surge Capabilities |
IEC 1000-4-5, 8/20µs @ 10kA |
Frequency Range |
2.0 to 6.0 GHz |
Return Loss |
> 20 dB |
Insertion Loss |
≤ 0.2 dB |
RF Power |
10W |
Temperature Operating/Storage |
-40°to 85°C |
Relative Humidity |
0 to 100% condensing |
Surge Throughput Energy |
≤ 0.5µJ (6kV/3kA 8/20µs) |
Peak Let-Through Voltage |
± 3V (6kV/3kA 8/20µs) |
To contact Prosoft Technology about RadioLinx Lightning Protection | LP-24002 / LP-24003 use Get a quote.
Features and Benefits
LP-24002
The LP-24002 lightning protection is designed for use inside an enclosure with the bulkhead fitting protruding through the enclosure. The connectors are standard N jack connector to standard N jack BH connector. The bulkhead fitting can be connected to any standard N type connector extension cable.
LP-24003
The LP-24003 lightning protection is designed for use inside an enclosure with the bulkhead fitting protruding through the enclosure and connecting to a N plug barrel adapter. This can then connect to any antenna with a standard N type connector.
Applications
RadioLinx Lightning Protection is designed to protect the radio in the event of a lightning strike. A minimum 6 gauge copper wire should be used to connect the lightning protection to earth ground.
Hardware Specifications
Surge Capabilities |
IEC 1000-4-5, 8/20µs @ 10kA |
Frequency Range |
2.0 to 6.0 GHz |
Return Loss |
> 20 dB |
Insertion Loss |
≤ 0.2 dB |
RF Power |
10W |
Temperature Operating/Storage |
-40°to 85°C |
Relative Humidity |
0 to 100% condensing |
Surge Throughput Energy |
≤ 0.5µJ (6kV/3kA 8/20µs) |
Peak Let-Through Voltage |
± 3V (6kV/3kA 8/20µs) |
To contact Prosoft Technology about RadioLinx Lightning Protection | LP-24002 / LP-24003 use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product