| Spectral Range | 350–2500 nm |
| Spectral Resolution (FWHM) | 3 nm @ 350–1000 nm 8 nm @ 1500 nm 6 nm @ 2100 nm |
| Sampling Bandwidth | 1 nm increments (2151 channels reported) |
| Spectrometer Type | 3 Diffraction Gratings |
| Detectors | 512-element UV-enhanced TE-cooled Si Array; Two 256-element TE-cooled extended InGaAs arrays |
| Calibration | Factory calibrated for radiance and/or irradiance using NIST traceable source |
| Noise Equivalence Radiance | W/cm²/nm/sr (1.2 m fibre optic): 0.2×10-9 @ 400nm 0.2×10-9 @ 700nm 0.9×10-9 @ 900nm 1.2×10-9 @ 1500nm 1.8×10-9 @ 2100nm |
| Stray Light | =0.1% VNIR: <0.03% SWIR: <0.02% |
| Software Included | DARWin™ SP Data Acquisition |
| Power | 7.5 V, 30 W |
| Dimensions (mm) | 315 x 221 x 112 |
| Weight | 5.73 kg |
| Interface | USB, Wireless Connection |
| Integration Time | 1 – 1000 ms |
| Match Radiance | VNIR: 10 x Solar; SWIR: 2 x Solar |
| Wavelength Reproducibility | 0.1 nm |
| Wavelength Accuracy | 0.5 nm |
| Automatic Exposure | Yes |
| Shutter for Dark Scans | Yes |
| TTL & Phototriggering | No |
To contact Portable Analytical Solutions Pty Ltd about Spectral Evolution NIR Analyser | CalibraSpec 4500A use Get a quote.
The CalibraSpec 4500A spectroradiometer delivers exceptional stability and precision, specifically designed for calibration transfer workflows and a variety of demanding spectral measurement uses.
| Spectral Range | 350–2500 nm |
| Spectral Resolution (FWHM) | 3 nm @ 350–1000 nm 8 nm @ 1500 nm 6 nm @ 2100 nm |
| Sampling Bandwidth | 1 nm increments (2151 channels reported) |
| Spectrometer Type | 3 Diffraction Gratings |
| Detectors | 512-element UV-enhanced TE-cooled Si Array; Two 256-element TE-cooled extended InGaAs arrays |
| Calibration | Factory calibrated for radiance and/or irradiance using NIST traceable source |
| Noise Equivalence Radiance | W/cm²/nm/sr (1.2 m fibre optic): 0.2×10-9 @ 400nm 0.2×10-9 @ 700nm 0.9×10-9 @ 900nm 1.2×10-9 @ 1500nm 1.8×10-9 @ 2100nm |
| Stray Light | =0.1% VNIR: <0.03% SWIR: <0.02% |
| Software Included | DARWin™ SP Data Acquisition |
| Power | 7.5 V, 30 W |
| Dimensions (mm) | 315 x 221 x 112 |
| Weight | 5.73 kg |
| Interface | USB, Wireless Connection |
| Integration Time | 1 – 1000 ms |
| Match Radiance | VNIR: 10 x Solar; SWIR: 2 x Solar |
| Wavelength Reproducibility | 0.1 nm |
| Wavelength Accuracy | 0.5 nm |
| Automatic Exposure | Yes |
| Shutter for Dark Scans | Yes |
| TTL & Phototriggering | No |